FTKT

Available in the capacities of 3.52, 5.28, and 6.20 kW, Daikin’s FTKT Series of air conditioners gives an unmatched air conditioning experience.

Type : inverter
Star rating : 3
Available in kw(tr): 3.52(1), 5.28(1.5), 6.20(1.8)
Color : white

Category:
Share:

Available in the capacities of 3.52, 5.28, and 6.20 kW, Daikin’s FTKT Series of air conditioners gives an unmatched air conditioning experience.

Product Category : split hi-wall air – FTKT
Available in kw(tr): 3.52(1), 5.28(1.5), 6.20(1.8).

Model nameIndoor unitFTKT35TV16WCFTKT50TV16VCFTKT60TV16UC
Outdoor unitRKL35TV16WCRKT50TV16VCRKT60TV16UC
Power supply1 50Hz 230V1 50Hz 230V1 50Hz 230V
(220-240V)(220-240V)(220-240V)
 Power supply intakeOutdoor unitOutdoor unitOutdoor unit
Cooling capacity Rated Full/Half (min.~max.)kW3.52 / 1.76 (1.07 ~3.7)5.28/2.64 (1.75~5.7)6.2/3.1 (1.75~6.5)
Cooling capacity Rated Full//Half (Min.~Max.)Btu/h12000 / 6000 (3650~12600)18000/9000 (6000~19500)21200/10600 (6000~22200)
Power consumption Rated Full/Half (min.~max.)W1200 / 385 (210 – 1200)1790/582(370-1950)1970/722 (350-2100)
Annual Power consumptionkWh682.271024.931202.77
ISEER / Star RatingWh/Wh3.99 / 3*3.99 / 3*3.99 / 3*
Voltage RangeV160-265160-265160-265
Operating currentCoolingA5.437.868.67
Indoor unit
Panel colour WhiteWhiteWhite
Dimensions HxWxDmm298 x 800 x 229298 x 885 x 229298 x 885 x 229
(Package dimensions) 375 x 895x 325375 x 980 x 325375 x 980 x 325
Weight (Gross)kg10(14)11(16)11(16)
Airflow rate *1 X(Y)m3/min.13.4(11.9)16.2 (14.3)16.6 (15.4)
Feet3/min (CFM)473(420)572(505)586(544)
Operation sound H/M/L/SLCoolingdBA40/36/32/29/2645/42/40/38/3547/45/43/40/38
Outdoor unit
Dimensions (HxWxD)mm550x675x284595x845x300595x845x300
(Package dimensions) 620x825x400680x1035x410680x1035x410
Weight (Gross)kg22 (28)29 (36)33 (40)
Operation sound (H)CoolingdBA515456
Refrigerant (Amount) R32 (0.53 kg)R32 (.68kg)R32 (1.00 kg)
Breaker sizeA152020
Piping lengthCharge-lessm101010
Max. lengthm202030
Max. heightm151020
Piping connectionGas/Liquidmm9.5/ 6.412.7/ 6.412.7/ 6.4
Operation limitCoolingoCDB19.4~5419.4~5419.4~54

Measurement conditions

  • Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.
  • Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Cooling and heating capacities above are rounded off to first decimal. 1TR (Ton of Refrigeration) = ~3.517 kilowatt. For the complete feature list please refer pages 49 – 52.

* X(Y) X-Air flow rate during fan operation.
Y-Air flow rate in wet (cooling) condition.