ETKL

Experience the best in air conditioning with Daikin’s new-age ETKL series. It promises to cool you as soon as you turn on the air conditioner.

Type : inverter
Star rating : 3
Available in kw(tr): 3.5(1), 5(1.5)
Color : white

Category:
Share:

Experience the best in air conditioning with Daikin’s new-age ETKL series. It promises to cool you as soon as you turn on the air conditioner. With just the touch of a button, you will get a world-class air conditioning experience you never felt before.

Product Category : split hi-wall air
Conditioner– ETKL
Available in kw(tr): 3.5(1), 5(1.5)

Color : white

specification

Model nameIndoor unitETKL35TV16WCETKL50TV16VC/F
Outdoor unitRKL35TV16WCRKL50TV16VC/F
Power supply1 50Hz 230V1 50Hz 230V
(220-240V)(220-240V)
 Power supply intakeOutdoor unitOutdoor unit
Cooling capacity Rated Full/Half (min.~max.)kW3.52 / 1.76 (1.07 ~3.7)5.0/2.5 (1.75~5.2)
Cooling capacity Rated Full/Half (min.~max.)Btu/h12000 / 6000 (3650~12600)17100 / 8550 (6000~17700)
Power consumption Rated Full/Half (min.~max.)W1200 / 385 (210 – 1200)1670 / 557 (375~1750)
Annual Power consumptionkWh682.27969.25
ISEER / ISEER RANKWh/Wh3.99/3*3.99/3*
Voltage RangeV160-265160-265
Operating currentCoolingA5.437.41
Indoor unit
Panel colourWhiteWhite
Dimensions HxWxDmm298 x 800 x 229298 x 885 x 229
(Package dimensions)mm375 x 895 x 325375 x 980 x 325
Weight (Gross)kg10 (14)11 (16)
Airflow rate *1 X(Y)m3/min.13.4 (11.9)16.2 (14.3)
Feet3/min (CFM)473 (420)572 (505)
Operation sound H/M/ML/L/SLCoolingdBA40/36/32/29/2645/42/40/38/35
Outdoor unit
Dimensions (H x W x D)mm550x675x284595x845x300
(Package dimensions)mm620x825x400680x1035x410
Weight (Gross)kg22 (28) / 22 (26)28 (35)/ 28 (33)-29 (36)/29 (34)
Operation sound H/LCoolingdBA5154
Breaker sizeA1520
Piping lengthCharge-lessm1010
Max. lengthm2020
Max. heightm1510
Piping connectionGas/Liquidmm9.5/ 6.412.7 / 6.4
Operation limitCoolingoCDB19.4~5219.4~52

Measurement conditions

  • Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.
  • Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Cooling and heating capacities above are rounded off to first decimal. 1TR (Ton of Refrigeration) = ~3.517 kilowatt.

* X(Y) X-Air flow rate during fan operation.
Y-Air flow rate in wet (cooling) condition.